Tia/eia-568-b

Developing the TIA/EIA Standard

By 1985, a number of telecommunications companies started to be concerned (publicly) about the lack of a Ethernet cabling standard that was not controlled by a commercial interest (AT&T). As a result, the Computer Communications Industry Association (CCIA) made a request to the Electronics Industry Association (EIQ) to develop such a standard. These efforts took almost six years until the first draft was released in the summer of 1991.

The new standard was labeled EIA/TIA-568 and included much of the work included in the existing AT&T defacto standard of the time. The standard also included a means to support telephones that use two pairs vice one pair of cable which allowed operations on both pairs one and two. Later that year, TSB-36 (Technical Systems Bulletin 36) was issued that included guidance for both category 4 and category 5 cable connections. The next year, TSB-40 was issued which included guidance for using the higher speed UTP for connecting hardware. This bulletin was later updated (January 1994) to cover both fly leads and Rj45 modular jacks.

During this same timeframe, the TIA/EIA-568 standard was updated to officially declare the connector specification to be TIA/EIA 568A and included the existing 258A AT&T standard under a new name/designation of TIA/EIA 568B. Since both standards were widely deployed at the time, they were both included into the International Standard, Generic Cabling for Customer Premises Cabling, ISO/IEC 11801:1995.

Примечания

  1.  (англ.). Дата обращения 12 мая 2013.
  2. . 090917 nag.ru
  3.  (англ.). Дата обращения 12 мая 2013.
  4. Из стандарта ANSI/TIA/EIA-568-B-2 для магистралей
  5.  (англ.) (недоступная ссылка). Donutey. Дата обращения 1 апреля 2011.
  6.  (англ.). Electronic Products.
  7.  (англ.). Дата обращения 12 мая 2013.
  8.  (англ.). Panduit (27 February 2004). Дата обращения 12 мая 2013.
  9.  (англ.). B&B Electronics.
  10. IEEE Std 802.3-2008, Institute of Electrical and Electronics Engineers, 2008, Table 13-1
  11.  (англ.). The Network Encyclopedia. Дата обращения 12 мая 2013.
  12. , Satelliete & Cable TV. Проверено 5 января 2013.
  13. ↑ .
  14. ↑ .
  15. ↑  (англ.). PowerStream. Дата обращения 12 мая 2013.
  16. IEEE 802.3at-2009 Table 33-11
  17.  (англ.) (недоступная ссылка).
  18. . Дата обращения 4 июля 2012. 090127 unioncopper.com
  19. . 090113 prc68.com
  20. ↑  (англ.) (PDF). Belden.
  21.  (англ.). Дата обращения 12 мая 2013.
  22.  (недоступная ссылка). Дата обращения 1 апреля 2011.
  23. . 090126 broadbandreports.com
  24. . 090126 broadbandreports.com
  25. . 090126 sawaal.ibibo.com

Подключение сетевых устройств на основе медного кабеля

Для начала рассмотрим подключения сетевых устройств на основе медного кабеля. Обычно это витая пара Категории 5 и Категории 5E (Cat 5 и Cat 5E соответственно). Такой кабель содержит 8 жил.

Для того чтоб кабель мог использоваться как среда передачи данных, его нужно «оконцевать», то есть, на его концы поставить некоторые разъемы, которые называются RJ45 коннекторы.

Существует два стандарта, по которым «обжимают» кабель:

  • T568A
  • T568B

Если рассматривать 10мб и 100мб технологии передачи данных (10BASE-T и 100BASE-TX соответственно), то тут используется всего 2 пары (4 проводника), остальные 2 пары не используются. В таком случае каждая пара используется для передачи в каждом из направлений. Например, сетевая карта компьютера передает данные по 1,2 проводникам, а получает по 3 и 6. А коммутатор работает наоборот, по 1 и 2 контакту он получает, а по 3 и 6 отправляет данные. Поэтому существует два вида подключения устройств между собой. Если устройства одного типа (например компьютер-компьютер, коммутатор — коммутатор, и др), то используется cross-over соединение, а если устройства различного типа (например, компьютер — коммутатор), то используется прямое (straight-throught) соединение.

Для прямого подключения используется с обоих сторон одинакового стандарта, T568A — T568A или T568B — T568B.

Для обратного, T568A-T568B.

Если представить в графическом виде, то это будет выглядеть таким образом:

Многое совеременное оборудование «понимает», какой кабель подключен к устройству, и если например подключен кабель, который «обжат кроссом», то оборудование автоматически подстраивается под него(меняет пары). Так скажем, защита от «дурака». Такая технология называется Auto-MDIX. Данная функция поддерживается не во всех моделях коммутаторов Cisco.

LonWorks

Кратко представим кабели, разработанные и производимые на НПП «Спецкабель», которые используются для технологии LonWorks компании Echelon Corporation, изначально предназначенной для систем автоматизации жизнеобеспечения зданий, а затем постепенно нашедшей широкое применение в различных областях промышленности и транспорта. Официальное признание данной технологии определяется стандартом EIA-709 Ассоциации Производителей Бытовой Электроники (CEMA – Customer Electronics Manufactures Association) в области автоматизации жилых помещений (Home Automation). Согласно данному стандарту сеть управления LonWorks поддерживает различные среды передачи данных: симметричные кабели на основе «витой пары», коаксиальный кабель, радио- и инфракрасный канал, силовые линии. Наряду с привычными типа ми сетевых топологий (шина, звезда, кольцо) в технологии LonWorks существует так называемая свободная или произвольная топология (Free Topology), позволяющая в рамках одного сегмента (управление климатом, освещением, системами безопасности, контролем доступа и пр.) комбинировать в системах управления зданиями все три стандартных типа топологии. Free Topology является наиболее популярной в системах управления зданиями, поскольку лучше всего соответствует внутренней разводке в помещениях. Общая спецификация на протокол LonTalk, который лежит в основе LonWorks, установлена в ANSI/EIA/CEA-709.1, а в двух других частях (709.2 и 709.3) устанавливается спецификация сетей управления на основе силовых линий и спецификация произвольной топологии на основе «витой пары» соответственно. Согласно последней, тип кабеля, рекомендуемый для сетей данной спецификации, должен удовлетворять требованиям, предъявляемым к неэкранированным кабелям категории 5 стандарта ANSI/EIA/TIA 586A с размером проводника 24 AWG.

Рис.9

НПП «Спецкабель» разработало и производит по ТУ16.К99-024-2005 две марки кабелей с исполнением без экрана и в экране, соответствующих спецификации EIA-709.3. Конструкция неэкранированных ка белей следующая: кабели для автоматизации (КА) с одной или двумя парами скрученных однопроволочных медных проводников диаметром 0,64 мм (22AWG), изолированных пористым полиэтиленом, заключенными в общую защитную оболочку из светостабилизированного полиэтилена (П), поливинилхлоридного пластиката (В) или безгалогенной композиции (П-NH). Конструкция экранированных кабелей аналогична, но с тем отличием, что скрученные пары заключены в общий экран (Эф), состоящий из алюмолавсановой ленты с проложенным под ней дренажным многопроволочным медным луженым проводником (рис. 9).

Таблица 5
Тип канала Марка кабеля Длина магистрального кабеля (максимальное расстояние между узлами), м Длина ответви- тельного кабеля, м
TP/FT-10 (произвол. технология) КАВ, КАВЭф 500 (400)
КВП, КВПЭф 450(250)
КСПВЭВ 500 (320)
TP/FT-10 (шинная технология) КАВ, КАВЭф 1400 3
КВП, КВПЭф 900
КСПВЭВ
TP/XF-78 КАВ, КАВЭф 1400
TP/XF-1250 КАВ, КАВЭф 130 0,3
КВП, КВПЭф

Необходимо отметить, что данные марки кабелей соответствуют спецификации кабеля типа Level IV NEMA (национальной ассоциации производителей электротехнической промышленности – National Electrical Manufacturers’ Association), который рекомендован самой компанией Echelon для трех применяемых в сетях LonWorks типов каналов с различными скоростями передачи данных – TP/FT-10 (канал произвольной/свободной и шинной топологии, 78 кБит/с, соответствует стандарту EIA-709.3), TP/ХF-78 и TP/ХF1-1250 (каналы шинной топологии, 78 кБит/с и 1,25 Мбит/с). Данный кабель является универсальным для всех трех типов каналов. Для канала TP/FT-10 компания Echelon также рекомендует и другие типы кабелей такие, как обычный кабель 5-й категории по стандарту TIA 586A (также может использоваться для TP/ХF-1250) и кабель типа JY(st)Y (диаметр проводника 0,8 мм). Соответствующие этим типам кабели, разработанные и производимые на НПП «Спецкабель», имеют марки КВП или КВПЭф и КПСВЭВ (с диаметром проводников 0,52 и 0,8 мм) соответственно (табл. 5). Помимо этого сети LonWorks могут использовать канал TP-RS-485 с интерфейсом RS-485 в основе. В этом случае НПП «Спецкабель» для применения рекомендует кабели сер. RS-485, рассмотренные выше.

¿Qué es el cable cruzado?

Un cable de red cruzado es un tipo de cable Ethernet que se utiliza para conectar dispositivos de computación directamente. A diferencia de los cables de red directo, los cables cruzados utilizan dos estándares de cableado diferentes: un extremo usa el estándar de cableado T568A y el otro utiliza el estándar de cableado T568B (T568A a T568B). El cableado interno de los cables de red cruzados invierte las señales de transmisión y recepción. Este tipo de cable se usa con más frecuencia para conectar dos dispositivos del mismo tipo: por ejemplo, dos ordenadores (a través del controlador de interfaz de red) o dos switches entre sí.

Схемы обжима

Нумерация в штекере 8P8C

Существует два варианта обжима разъёма на кабеле:

  • для создания прямого кабеля — для соединения порта сетевой карты с коммутатором или хабом,
  • для создания перекрёстного (использующего кроссированный MDI, англ. MDI-X) кабеля, имеющего инвертированную разводку контактов разъёма для соединения напрямую двух сетевых плат, установленных в компьютеры, а также для соединения некоторых старых моделей свитчей или роутеров (uplink-порт).

Обжимается разъём 8P8C (зачастую ошибочно именуемый RJ45).

Вариант по стандарту TIA/EIA-568A

Вариант по стандарту TIA/EIA-568B (используется чаще)

Перекрёстный кабель (crossover cable)

Основная статья: Кросс-кабель Ethernet

Предназначен для соединения однотипного оборудования (например, компьютер-компьютер). Однако большинство современных сетевых устройств способно автоматически определить метод обжима кабеля и подстроиться под него (Auto MDI/MDI-X), и перекрёстный кабель сегодня потерял свою актуальность.

Вариант для скорости 100 Мбит/с

Вариант для скорости 1000 Мбит/с

Устройства стандарта 1000BASE-T сами определяют верную раскладку кабеля благодаря технологии Auto-MDIX (её реализация требуется стандартом 1000BASE-T).

Консольный кабель (rollover cable)

Основная статья: Консольный кабель

Один конец этого кабеля обжат по обратной схеме относительно другого, как если бы вы перевернули его и посмотрели бы на него с другой стороны. Используется для настройки маршрутизатора или коммутатора с помощью компьютера. Применяется в основном в оборудовании Cisco. Как правило голубого цвета.

Схема обжима

Общие положения

Обжимной инструмент (кримпер)

Рабочая часть кримпера: для восьми-, шестиконтактных разъёмов и регулируемый резак, позволяющий снять внешнюю изоляцию, без повреждения проводов пар.

Пара 1-2 (TDP-TDN) используется для передачи от порта MDI к порту MDI-X, пара 3-6 (RDP-RDN) используется для приёма портом MDI от порта MDI-X. Эти пары требуются всегда. Пары 4-5 и 7-8 применяются в зависимости от потребности (например, при использовании кабеля категории 3 в спецификации 100Base-T4) и обычно двунаправленные.

Обозначение Описание
1 TX+ (TXP) Прямой сигнал передачи
2 TX- (TXN) Инверсный сигнал передачи
3 RX+ (RXP) Прямой сигнал приема
4
5
6 RX- (RXN) Инверсный сигнал приема
7
8

Использование кабеля, обжатого не по стандарту, может привести (в зависимости от длины кабеля) к тому, что кабель не будет работать совсем или будет очень большой процент потерь передаваемых пакетов.

Для проверки правильности обжатия кабеля, помимо визуального контроля, используют специальные устройства — кабельные тестеры. Такое устройство состоит из передатчика и приёмника. Передатчик поочерёдно подаёт сигнал на каждую из восьми жил кабеля, дублируя эту передачу зажиганием одного из восьми светодиодов, а на приёмнике, подсоединённому к другому концу линии, соответственно загорается один из восьми светодиодов. Если на передаче и на приёме светодиоды загораются подряд, значит, кабель обжат без ошибки. Более дорогие модели кабельных тестеров могут иметь встроенное переговорное устройство, индикатор обрыва с указанием расстояния до обрыва и пр

Указанная выше схема обжима подходит как для 100-мегабитного соединения, так и для гигабитного. При использовании 100-мегабитного соединения используются только две из четырёх пар, а именно оранжевая (1-2 TDP-TDN) и зелёная (3-6 RDP-RDN) пары. Синяя и коричневая пары могут остаться незадействованными, либо могут быть использованы для передачи питания в некоторых вариантах Power over Ethernet (PoE). Для обеспечения гигабитного соединения используются все четыре пары проводников стандартного кабеля.

Также существуют ограничения на выбор схемы перекрёстного соединения пар, накладываемые стандартом PoE. При прямом соединении пар в кабеле («один к одному»), этот стандарт будет работать автоматически.

What is the Purpose of CAT-5 Cable?

CAT-5 cable (Category 5) is designed to carry computer network information for networks such as Ethernet. The cable consists of twisted pair cable and provides performance guarantees of speeds up to 100 MHZ and can also be used to transport video or for telephony use. The cable standard is assessed as being sufficient for network speeds up to 1000BASE-T (Gigabit Ethernet) and is commonly connected using modular connectors or punch down blocks. Most CAT-5 cable is not shielded since it relies on differential signaling and the twisted pair design to help eliminate noise from the communications line. The 568B and 568A connector definitions can each be used with CAT-5 cable for termination of the cabling connection depending on the requirements of the termination point(s).

Как обжать витую пару 8 жил

Нам понадобятся обжимник, коннектор rj45, и витая пара, ножницы.

Шаг 1: Убираем наружную оболочки на конце кабеля примерно на 2,5 см от края. Далее разматываем витые провода и убираем все лишние.

Шаг 2: Зажмите провода между пальцами и выпрямляем их. Сортируем провода в правильном порядке так как описано выше.

Шаг 3: Укорачиваем провода так чтобы провода торчали приблизительно на 1,2-1,4 см. от края изоляции. Используйте ножницы, чтобы сделать прямой разрез по всем 8 проводам.

Шаг 4: Осторожно вставьте все 8 проводов в разъем RJ-45 как можно дальше и убедившись, что они остаются выровненными, и каждый цвет попал в соответствующий канал

Шаг 5: Вставляем до упора провода в разъем rj45, проверяем последовательность проводов. Далее вставляем коннектор в обжимник, в гнездо «Р8» и обжимаем коннектор до характерного щелчка.

Historia

El estándar TIA/EIA-568 se desarrolló gracias a la contribución de más de 60 organizaciones, incluyendo fabricantes, usuarios finales, y consultores. Los trabajos para la estandarización comenzaron en , cuando la “Asociación para la Industria de las Comunicaciones y las Computadoras” (CCIA) solicitó a la “Alianza de Industrias de Electrónica” (EIA), una organización de normalización, que definiera un estándar para el cableado de sistemas de telecomunicaciones. EIA acordó el desarrollo de un conjunto de normas, y se formó el comité TR-42 ​, para desarrollar el trabajo. Éste, sigue siendo mantenido por el TR-42, pero EIA ya no existe por lo cual ha sido eliminado del nombre.

La primera revisión del estándar, TIA/EIA-568-A.1-1991, se emitió en 1991 y fue actualizada en 1995. La demanda comercial de sistemas de cableado aumentó fuertemente en aquel período, debido a los avances de tecnológicos con respecto a ordenadores personales y redes de comunicación de datos. El desarrollo de cables de par trenzado de altas prestaciones y la popularización de fibras ópticas, llevaron también a actualizaciones significativas en el estándar. Dichos cambios fueron reflejados en la revisión C en 2009 y posteriormente reemplazados con la serie D ​

Кабельный стандарт

Спецификация для кабеля категории 5 была определена в ANSI/TIA/EIA-568-A, с уточнением в TSB-95. В этих документах указаны характеристики и требования к испытаниям на частотах до 100 МГц. Типы кабелей, типы разъемов и кабелей топологии определяются TIA/EIA-568-B. Кабель разводится по любой схеме: T568A или T568B. Обе схемы работают одинаково и могут использоваться беспорядочно, при условии, что одна схема используется для обоих концов кабеля. Почти всегда контакты разъёмов 8P8C, часто называемые RJ-45, используются для подключения кабеля категории 5. Стандарт USOC/RJ-61 используется для многоканальных телефонных соединений.

Каждая из четырех пар кабеля категории 5 имеет свой шаг скрутки, чтобы минимизировать наводки между парами. Хотя общепринятыми считаются кабельные сборки, содержащие 4 пары, 5-я категория не ограничивается 4 парами. В магистральных кабелях может использоваться до 100 пар. Использование уравновешенной линии позволяет сохранить высокое отношение сигнал-шум, несмотря на помехи от внешних источников и наводки от других пар. Кабели категории 5 наиболее часто используются для таких стандартов Ethernet, как 100Base-TX и 1000Base-T.

Кабель категории 5 может быть жёсткого «Solid» и гибкого «Stranded» типа. Кабель гибкого типа лучше гнётся, может выдержать большую нагрузку на изгиб без излома и подходит для надёжного соединения с разъёмами, прокалывающими изоляцию, но не подходит для надёжного соединения с разъёмами, смещающими изоляцию (IDC). Кабель жёсткого типа дешевле[источник не указан 3387 дней] и подходит для надёжного соединения с разъёмами, смещающими изоляцию, но не подходят для соединения с разъёмами, прокалывающими изоляцию. Кабели зданий (например, кабели внутри стен, которые соединяют розетки на стене с центральной патч-панелью) обычно жёсткие в то время, как соединительные кабели (например, подвижные кабели от розеток до компьютеров) — гибкие. Внешняя изоляция, как правило, из ПВХ или . Тип используемого кабеля можно определить по надписям на нём. Тип «Solid» имеет меньшие потери при передаче сигнала, именно поэтому его используют для магистральной прокладки по зданию.[источник не указан 2292 дня]

Требования к кабелям

Для кабелей стандартов 10BASE-T и 100Base-TX Ethernet требуется две пары проводников. Для кабелей стандарта 1000BASE-T Ethernet требуется четыре пары проводников. Кабели Cat 5 и Cat 5e обычно используют проводники AWG 24 — 26 из меди.

Максимальная длина сегмента кабеля

В соответствии со стандартом ANSI/TIA/EIA для медного кабеля категории 5е максимальная длина кабеля сегмента составляет 100 метров (328 футов). Если требуются более далёкие расстояния, необходимо использовать активные аппаратные средства, такие как повторитель или коммутатор. По стандарту 10BASE-T расстояние между активными устройствами не должно превышать 100 метров: 90 метров фиксированного кабеля, два коннектора и два коммутационных кабеля по 5 метров.

Различия категорий 5 и 5e

К кабелям и разъёмам категории 5е ужесточили требования и ввели новые спецификации перекрёстных помех. По стандарту максимальная частота передаваемых сигналов для кабелей категорий 5 и 5e одинакова — 100 МГц.

Изменённые параметры в категории 5e по сравнению с категорией 5
Параметр Категория 5 Категория 5e
Затухание отражённого сигнала ⩾ 16,0 дБ ⩾ 20,1 дБ
Переходное затухание на ближнем конце ⩾ 32,3 дБ ⩾ 35,3 дБ
Суммарное приведённое переходное затухание на ближнем конце не регламентировано ⩾ 32,3 дБ
Переходное затухание на дальнем конце не регламентировано ⩾ 23,8 дБ
Суммарное приведённое переходное затухание на дальнем конце не регламентировано ⩾ 20,8 дБ
Разность задержки не регламентировано ⩽ 45 нс

Подсистемы кабельной системы здания и кампуса

Структурированная кабельная система (СКС) состоит из совокупности подсистем, каждая из которых представляет набор кабелей, разъемов, соединителей и других продуктов, необходимых для экономичного решения проблемы передачи данных на данной территории. Согласно стандарту построения кабельных систем TIA/EIA 568 СКС имеет следующие характеристики:

Таблица 7.1. Максимальная длина магистрального сегмента

Вид кабеля Максимально допустимые расстояния
А (HC-MC) B (HC-IC) С (IC-MC)
Витая пара: 90 м 90 м 90 м
Многомодовое волокно: 2000 м 500 м 1500 м
Одномодовое волокно: 3000 м 500 м 2500 м

При использовании промежуточного кросса IC суммарное расстояние от HC до MC не должно превышать максимальной длины магистрального сегмента.

В стандарте TIA/EIA 568A определены следующие подсистемы структурированных кабельных систем:

  • Магистральная подсистема здания (building backbone);
  • Магистральная подсистема кампуса (campus backbone); кампус — это совокупность зданий, разнесенных на расстояния, не превышающие указанных в таблице 7.1;
  • Горизонтальная подсистема здания (horizontal subsystem);
  • Административная подсистема (administrative subsystem);
  • Подсистема рабочих мест (workplace subsystem).

Помещения (HC, IC, MC), , где находятся кабельные соединительные устройства называют телекоммуникационными клозетом – TC, а помещения, где находится сетевое оборудование, называют аппаратными – ER (в небольших системах их объединяют с телекоммуникационным шкафом). Покажем эти подсистемы на схеме и опишем подробнее.

Рис.7.2. Подсистемы СКС

Подсистема рабочего места служит для присоединения терминала, компьютера или телефона к горизонтальной подсистеме. Среда передачи — кабель UTP/STP/Coaxial. Присоединение осуществляется при помощи розетки рабочего места. Розетка может содержать специальный адаптер, согласующий сопротивление различных кабельных систем (balun).

Горизонтальная подсистема – это горизонтальная часть кабельной системы. Она соединяет телекоммуникационную розетку в зоне рабочих мест с административной подсистемой этажа в телекоммуникационном клозете.. Среда передачи – STP/UTP/Coaxial/Fiber.

Административная подсистема состоит из совокупности коммутационных кабелей (патчкордов), устройств (патчпанелей), соединительных разъемов и блоков, которые подсоединяют горизонтальную подсистему к вертикальной системе здания. Административная подсистема располагается в телекоммуникационных шкафах.

Магистральная подсистема здания (Building Backbone) – вертикальная магистраль здания. Она обеспечивает соединение между узлами административной подсистемы. Среда передачи – UTP/Coaxial/Fiber. Подсистема имеет топологию звезда, в которой каждый горизонтальный клозет (НС) соединен кабелем с главным (MC) или промежуточным (IC) клозетом.

Campus Backbone (Metropolitan Backbone) – кампусная магистраль соединяет различные здания на ограниченной территории. В таблице 7.1 показано, что согласно стандартам протяженность этой магистрали определяется видом оптоволокна и составляет 2500 м для многомодового волокна и 3000 м для одномодового. В общем, такая ограниченная территория соответствует территории локальной сети. Средой передачи обычно является оптоволокно. Топология подсистемы – звезда, в центральном здании находится главный кросс. В главном клозете здания или кампуса осуществляется подключение к городской магистрали или глобальной сети (WAN). Если в кампусе несколько зданий, то главный клозет устраивают в том здании, к которому подходит городская магистраль, а в каждом из остальных зданий устраивается промежуточный клозет.

История

Перекрещивание проводов на телеграфном столбе.

Первые телефоны использовали телеграфные линии, или однопроводные линии с цепью заземления, проложенные открытым способом. В 1880 году во многих городах были пущены электрические трамваи, которые наводили много шумов на эти линии. Судиться было бесполезно, и телефонные компании переделывают свои линии в сбалансированную схему, имевшую дополнительную выгоду, заключавшуюся в снижении затухания сигнала.

Когда линии электропередачи стали более распространённым явлением, этой меры оказалось недостаточно. Телеграфные провода шли параллельно с линиями электропередачи, и в течение нескольких лет растущее использование электроэнергии снова принесло увеличение помех, поэтому инженеры разработали метод транспозиции проводов, чтобы свести на нет помехи.

В транспозиции проводов их положение менялось через определённое количество опор. Таким образом, два провода сбалансированной пары получали аналогичные помехи от линий электропередачи. Это представляло собой раннюю реализацию скручивания с шагом транспозиции проводов около четырёх перекрестий на километр, или шесть на милю. Такие открытые симметричные линии с периодическими транспозициями дожили до наших дней в некоторых сельских районах.

Витая пара была изобретена Александром Грейамом Беллом в 1881 году. К 1900 году вся американская сеть телефонных линий была или на витой паре или на открытых проводах с транспозицией для защиты от помех.

Стандарт

Стандарт TIA / EIA 568-A, который был ратифицирован в 1995 году, был заменен стандартом TIA / EIA 568-B в 2002 году и с тех пор обновлен. Оба стандарта определяют выходы T-568A и T-568B для использования кабеля с не экранированной витой парой и разъемов RJ-45 для подключения Ethernet. Оба стандарта T-568A и T-568B являются наиболее часто используемыми в Ethernet-соединений. Приставка RJ означает Зарегистрированные Jacks. RJ-11 представляет собой 6-позиционное 4-жильное гнездо, используемое для телефонной проводки, а RJ-45 — 8-позиционное 8-жильное гнездо, используемое в 10BaseT и 100BaseT ethernet-проводке.